Used to monitor the density of SF6 gas in a sealed container, for example,
the high-pressured electric appliance and pressure transformer.
Dial Diameter: Φ1.5”;2”;2.5”
Case Material: Stainless steel 304; IP65
Lens: Safety glass
Dial:
Red zone-Restricted zone;Yellow zone-Danger zone
Green zone-Working zone (other dials are available upon request)
Pressure Range: 1.0 to 2.0 bar abs.;0~10 bar (Relative pressure)
Accuracy: CI. 2.0 at 20℃;CI. 3.0 at -40~+60℃
Measuring Element: Bourdon Tube, Tin-Silver solder
Mounting Type: Direct mounting- Back connection without flange
Connection: M24x 1.5;ZG1/8” male thread
Port material:
Copper Alloy or Stainless steel
M24x 1.5;ZG1/8" male thread
Sealability: Leak Rate ≤ 1 × 10-9Pa·m3/s
Temperature: Operation -40~+60℃(gas)